Safety I/O

With four safe input channels

  • by Kendrion
  • December 11, 2013
  • 1322 views
  • Safety I/O
    Safety I/O

As a new product of Kendrion Kuhnke's Ventura FIO series the yellow I/O terminal is operating via the safe EtherCAT-Protocol (FSOE) and can be integrated anywhere within this modular I/O system. The new Safety EtherCAT terminal Ventura FIO Safety I/O 4DI/2DO is a digital input and output module with four safe input channels and two safe output channels. The digital inputs connect to sensors with floating terminals. The failure-resistant outputs switch 24 V DC actors with a current of up to 2 A per channel. If the EtherCAT terminal detects a failure, it switches off automatically (fail stop). The Safety I/O conforms to the requirements of IEC 61508 SIL 3 and DIN EN ISO 13849 PL e. Besides this new safety module 4DI/2DO, a safety PLC and additional safety I/O modules will be included into the product portfolio of the company. On request, these modules are also available as custom-designed solutions tailored to a specific machine.

Disclaimer: Content published by TIM Global Media, including text, images, and videos, is either created in-house or provided by Suppliers/Manufacturers with their approval. Suppliers/Manufactures warrant that their materials do not infringe third-party rights and agree to indemnify and hold TIM Global Media harmless from any related claims.

Share with:

Anis Zenadji

Graduated in political sciences and international relations in Paris, Anis joined the team in early 2019. Editor for IEN Europe and the new digital magazine AI IEN, he is a new tech enthusiast. Also passionate about sports, music, cultures and languages. 

More articles Contact